Flame Lab
A plastic or fabric sample
1Sample
2The conditions
NASA tested 13.6% to 22.2%
NASA tested 0 to 28 cm/s
NASA tested 6.3 to 12.7 mm
Or start from a real cabin
3Show only
54 of 54 tests
Play NASA's video of test O3a
23.5 MB, streamed from NASA's archive. Nothing loads until you press play.
NASA footage · BASS-II test O3a
Test O3a. 18% oxygen · 3 cm/s air · 6.3 mm wide
NASA's own recording, unedited, from the PSI archive.
Ask the SI about this test
Measured here12 tests close to your setting
In 7 of 9 nearby tests with a known ending, the flame went out or was blown out.
How the 12 tests ended
- The flame went out
- Blown out by the air
- Burned until the fan stopped
Carbon monoxide left in the air
60 ppm
14950
In the middle for this sample
Oxygen used up
0.4 points
0.01.7
Low for this sample
Carbon dioxide left in the air
0.62%
0.282.24
Low for this sample
How these are counted
Each number is the middle value of the 12 nearby tests. The bar shows where it sits between the lowest and the highest NASA measured for this sample.
Tests near your setting
47 of this sample's 54 tests have NASA's video.
and 6 more close by
Where NASA tested: every acrylic rod test
The flame went outBlown out by the airBurned until the fan stoppedYour setting
Before you rely on this
BASS-II lowered the oxygen and never raised it above 22.2%, so a Moon habitat's air cannot be set here: no solid was burned in it. How each test ended was read from NASA's own table and report by an SI tool; no person has checked those readings yet. One step is 1 point of oxygen, or 5 cm/s of air speed, or a 25% change in size: tests within one step count as measured here, within two as close.